我们这里是brocade的光端交换机,其实那个厂家的都一样,原理在哪里,按照原理和架构去划分zone。 当然图形界面划分也很简单 Fabric OS (WOLFB300SWA) Fabos Version 6.4.2a WOLFB300SWA login: admin Password: ----------------------------------------------------------------- WOLFB300SWA:admin> WOLFB300SWA:admin> WOLFB300SWA:admin> WOLFB300SWA:admin> cfgshow Defined configuration: cfg: WOLFB300SWA P750lp1_hba1_HDS2300_0a zone: P750lp1_hba1_HDS2300_0a 1,0; 1,2 Effective configuration: cfg: WOLFB300SWA zone: P750lp1_hba1_HDS2300_0a 1,0 1,2 WOLFB300SWA:admin> zonecreate "P750lp1_hba1_HDS2300_0a","1,0;1,3" WOLFB300SWA:admin> cfg cfgactvshow cfgcreate cfgenable cfgsave cfgsize cfgadd cfgdelete cfgmcdtmode cfgsaveactivetodefined cfgtransabort cfgclear cfgdisable cfgremove cfgshow cfgtransshow WOLFB300SWA:admin> cfgadd error: Usage: cfgadd "arg1", "arg2" WOLFB300SWA:admin> cfgadd "P750lp1_hba1_HDS2300_0a","WOLFB300SWA" "P750lp1_hba1_HDS2300_0a" wrong type WOLFB300SWA:admin> cfgadd "WOLFB300SWA","P750lp1_hba1_HDS2300_0a" WOLFB300SWA:admin> cfgenable WOLFB300SWA You are about to enable a new zoning configuration. This action will replace the old zoning configuration with the current configuration selected. If the update includes changes to one or more traffic isolation zones, the update may result in localized disruption to traffic on ports associated with the traffic isolation zone changes Do you want to enable 'WOLFB300SWA' configuration (yes, y, no, n): [no] yes zone config "WOLFB300SWA" is in effect Updating flash ... WOLFB300SWA:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Nothing changed: nothing to save, returning ... WOLFB300SWA:admin> zoneshow Defined configuration: cfg: WOLFB300SWA P750lp1_hba1_HDS2300_0a; P750lp1_hba1_HDS2300_0a zone: P750lp1_hba1_HDS2300_0a 1,0; 1,3 zone: P750lp1_hba1_HDS2300_0a 1,0; 1,2 Effective configuration: cfg: WOLFB300SWA zone: P750lp1_hba1_HDS2300_0a 1,0 1,3 zone: P750lp1_hba1_HDS2300_0a 1,0 1,2 WOLFB300SWA:admin> cfg cfgactvshow cfgcreate cfgenable cfgsave cfgsize cfgadd cfgdelete cfgmcdtmode cfgsaveactivetodefined cfgtransabort cfgclear cfgdisable cfgremove cfgshow cfgtransshow WOLFB300SWA:admin> cfgremove "WOLFB300SWA","P750lp1_hba1_HDS2300_0a" WOLFB300SWA:admin> zonedelete "P750lp1_hba1_HDS2300_0a" WOLFB300SWA:admin> zonecreate "P750_hba1_HDS2300_0a","1,0;1,3" WOLFB300SWA:admin> cfgadd "WOLFB300SWA","P750_hba1_HDS2300_0a" WOLFB300SWA:admin> cfgenable WOLFB300SWA You are about to enable a new zoning configuration. This action will replace the old zoning configuration with the current configuration selected. If the update includes changes to one or more traffic isolation zones, the update may result in localized disruption to traffic on ports associated with the traffic isolation zone changes Do you want to enable 'WOLFB300SWA' configuration (yes, y, no, n): [no] yes zone config "WOLFB300SWA" is in effect Updating flash ... WOLFB300SWA:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Nothing changed: nothing to save, returning ... NB300SWA:admin> zoneshow Defined configuration: cfg: WOLFB300SWA P750lp1_hba1_HDS2300_0a; P750_hba1_HDS2300_0a zone: P750_hba1_HDS2300_0a 1,0; 1,3 zone: P750lp1_hba1_HDS2300_0a 1,0; 1,2 Effective configuration: cfg: WOLFB300SWA zone: P750_hba1_HDS2300_0a 1,0 1,3 zone: P750lp1_hba1_HDS2300_0a 1,0 1,2 WOLFB300SWA:admin> WOLFB300SWA:admin> zonecreate "P750_hba1_HDS2300_0a","1,0;1,3" WOLFB300SWA:admin> cfgadd "WOLFB300SWA","P750_hba1_HDS2300_0a" WOLFB300SWA:admin> cfgenable WOLFB300SWA WOLFB300SWA:admin> cfgsave 创建zone主要步骤如下: WOLFB300SWA:admin>zonecreate “P750lp2_hba2_HDS2300_1b","2,1;2,4" WOLFB300SWA:admin>cfgadd “WOLFB300SWB”,” P750lp2_hba2_HDS2300_1b” WOLFB300SWB:admin> cfgenable WOLFB300SWB WOLFB300SWB:admin> cfgsave WOLFB300SWB:admin> cfgshow WOLFB300SWB:admin> zoneshow |
2023-10-27
2022-08-15
2022-08-17
2022-09-23
2022-08-13
请发表评论