hommatic, MAX and FHTTK contact sensors (door, window)
HM-SEC-WIN, HM-SEC-KEY
HM-Sen-LI-O
presence, ROOMMATE, GUEST
SONOS (power, volume)
harmony scenes
temperature and humidity sensors
CO20 and netatmo air quality sensor
RESIDENTS module
probably some more ...
simple config
for devices that are not correctly identified use the genericDeviceType attribute to configure the device type.
supported values are: security,ignore,switch,outlet,light,blind,thermometer,thermostat,contact,garage,window,lock
this is probably mostly used for differentiating between switches and lights.
enhanced config
for devices that don't use the autodetected readings and commands or for devices that mix readings from different
devices use the homebridgeMapping attribute. it is parsed from left to right and works as follows:
the genericDeviceType attribute is used to determine the service type that should be used for this device
in addition to the symbolic names above all homekit Service names are recognized
the homebridgeMapping attribute containts a space separated list of characteristic descriptions
each description consists of the characteristic name followed by a = followed by a komma separated list of parameters
each parameter can be of the form
<command>:<device>:<reading> where parts can be omitted from left to right or
<name>=<value>
the name of an already mapped characteristic to copy the configuration from there
the special clear to clear the mappings for the current characteristic
linkedTo=<service-name> to link the current service to <service-name>
characteristic names can be given as <service_name>#<characteristic_name> to create multiple services for a device
this can also include a subtype like so: <service_name>(<subtype>)#<characteristic_name> to create multiple services of the same type
the following special values for a description are recognized: clear -> clears all mappings for this device
e.g:
this would define a thermostat device with a command target to set the desired temperature, a reading target that indicates the desired target temperature, the desired min, max and step values and a current temeprature comming from the temperature reading of the device myTemp.
the names for the stadard service and characteristic types can be found here: .../hap-nodejs/lib/gen/HomeKitTypes.js
Currently supported values for Characteristic names are:
On
Brightness
Hue
Saturation
CurrentTemperaure
TargetTemperature
CurrentRelativeHumidity
CurrentAmbientLightLevel
AirQuality
CurrentDoorState
OccupancyDetected
StatusLowBattery
SecuritySystemCurrentState
SecuritySystemTargetState
FirmwareRevision
and all other homebridge Characteristic names
FHEM -> Homekit parameters:
minValue, maxValue, minStep: for all int and float characteristics -> the allowed range for this value in homekit
max: Hue and Saturation characteristics -> the range the reading has in fhem, only if different from minValue and maxValue
nocache: don't cache values for this reading
subtype: unique value necessary if multiple characteristics of the same type are in an accessory.
factor: multiply reading with this value
threshold: reading is mapped to true if the value is greater than the threshold value and to false otherwise
invert: invert the reading, taking minValue, maxValue into account
part: the reading value will be splitted at spaces and the n-th item is used as the value. counting starts at 0
values: a ; separated list that indicates the mapping of reading values to homekit values.
each list entry consists of a : separated pair of from and to values
each from value can be a literal value or a regex of the form /regex/
each to value can be a literal value or a homekit defined term for this characteristic
if to is exactly # then it is set to the current value. usefull for regex ranges
valueOn, valueOff: the reading values that are mapped to the true/false resp. on/off states in homekit. shotcut for values
if only one is given all values not matching this one are automatically mapped to the other
default: value to use if no reading is found or if none of values/valueOn/valueOff matches
timeout: timeout in ms after which the homebridge value is reset to the default value -> used to simulate push buttons
valid: a ; separated list of valid values for this characteristic,
each to value can be a literal value or a homekit defined term for this characteristic
readOnly: if set to true: make this charateristic read only. ignore any changes made by homekit
the order of the transformations is as follows: eventMap, part, threshold, values, valueOn/valueOff, factor, max, maxValue/minValue/minStep, invert
instead of using the transformation chain reading2homekit can be set to the name of a js function that is imported from a file
named by the jsFunctions config option. relative paths are relative to the same path the config file is located in.
the function it will be called with mapping and reading value as parameters and has to return the value to be used with homekit.
for custom characterisitcs the additional parameters name, format and unit have to be set. e.g.:
adding a history characteristic will try to use fakegato-history to create Eve compatible history entries for ContactSensor and TemperatureSensor services:
history:size=1024
Homekit -> FHEM parameters:
delay: true/<number> -> the value ist send afer one second/<number>ms of inactivity
factor: divide homekit value by this factor
maxValue: for all int and float characteristics -> the allowed range for this value in homekit
max: the max value the reading has in fhem, only if different from maxValue
cmd: the set command to use: set <device> <cmd> <value>
cmdOn, cmdOff: for all bool characteristics
cmds: a ; separated list that indicates the mapping of homekit values to fhem values.
each list entry consists of a : separated pair of from and to values
each from value can be a literal value or a homekit defined term for this characteristic or a regex of the form /regex/
each to value has to be a literal value
the order of the transformations is as follows: invert, factor, max/maxValue
precedence for mapping of homekit value to commands is in increasing order: cmd, cmdOn/cmdOff, cmds
instead of using the transformation chain homekit2reading can be set to the name of a js function that is imported from a file
named by the jsFunctions config option. relative paths are relative to the same path the config file is located in.
the function it will be called with mapping and the homekit value as parameters and has to return the value to be used with the fhem set command.
a dummy with a setList of exactly two entries will be mapped to a On characteristic where the first entry will be mapped to on and the second to off.
instead of the format described above homebridgeMapping can also contain the same data encoded as json
this has to be used if any of the separators above are used in an command or value. at the moment the
json version replaces all build in defaults for a device. e.g.: